Conventional Heat Detector
+
  • Conventional Heat Detector

分享到

Conventional Heat Detector

All of the HD912 series detectors meet the requirements of UL521 and EN 54-5 for use in fire alarm signaling systems, which provide fast and reliable response for heat 57°C (135°F) or Rate-of-Rise detection, They are intended for use in 2-wire/4-wire Class A2 supervised zone circuits. The HD912 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.

需要先拿到样品,联系我们!

查看类似产品

标签列表

  • 产品描述
  • Conventional Heat Detector

    All of the HD912 series detectors meet the requirements of UL521 and EN 54-5 for use in fire alarm signaling systems, which provide fast and reliable response for heat 57°C (135°F) or Rate-of-Rise detection, They are intended for use in 2-wire/4-wire Class A2 supervised zone circuits. The HD912 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.

    Product Features:

    • 2 or 4 wire models
    • Advanced detection and discrimination algorithms
    • Easy installation and maintenance
    • Sleek low-profile housing design
    • Durable sensor head, no need for replacement
    • SMD circuit board design-satisfactory quality and reliability guaranteed
    • N/C (normal/close)-N/O (normal/open)selectable relay output
    • AR (Auto Reset) function for security systems (optional for 4 wire models) Sensor base option:
    • standard and Shottky Diode
    • Five-year limited warranty

    The range includes:

    HD912-2

    2 wire heat alarm

    HD912-2L

    2 wire heat alarm with remote LED output

    HD912-4

    4 wire heat alarm (12/24VDC)

    HD912-4B

    4 wire heat alarm with buzzer (12/24VDC)

    HD912-4AR

    4 wire heat alarm with auto-reset function (12/24VDC)

    HD912-4ARB

    4 wire heat alarm with auto-reset function and buzzer (12/24VDC)

    Product Data:

    Response Temperature:

    Fixed termperature: 57°C (135° F)
    Rate-of-Rise: CLASS 2 (EN54-5); or 8°C/Min (UL521)

    Ceiling Spacing:

    50 foot rating for heat sensor

    Reset Voltage:

    less than 1 volt

    Alarm Indicator:

    LED continuously emitting red light

    Remote Output:

    25 mA max., diode gate

    Temperature Range:

    -10°C to 50°C

    Permissible Current:

    80mA maximum

    Humidity:

    0 to 95% RH, no condensation or icing

    Alarm Contact:

    (for 4-wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC

    Dimensions:

    100mm (dia) x 46mm (ht) with base

    Weight:

    120g/set with base

Conventional Heat Detector

All of the HD912 series detectors meet the requirements of UL521 and EN 54-5 for use in fire alarm signaling systems, which provide fast and reliable response for heat 57°C (135°F) or Rate-of-Rise detection, They are intended for use in 2-wire/4-wire Class A2 supervised zone circuits. The HD912 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.